Failed
30
ZPC/HPS/DPA021562
Single Lot
Direct Procurement Method
Work (Non Complex Works)
Zimbabwe PPDPA Act Rules
Internally Generated Funds
HWANGE POWER STATION
Engineering Consultancy
60 Day(s)
18-Jul-2024 08:18 AM
UNIT 5 TURBINE CASING REPAIRS BY GUASTINI POWER SERVICES FZCO DUBAI AT HWANGE POWER STATION
Project Name: UNIT 5 TURBINE CASING REPAIRS BY GUASTINI POWER SERVICES FZCO DUBAI AT HWANGE POWER STATION |
Description: UNIT 5 TURBINE CASING REPAIRS BY GUASTINI POWER SERVICES FZCO DUBAI |
Item No. | UNSPSC | Lot Name | Lot Description | Quantity | Unit of Measure |
---|---|---|---|---|---|
1 | 73152103 | Engineering equipment maintenance services | HP outer casing top and bottom halves cleaning | 1 | Work |
2 | 73152103 | Engineering equipment maintenance services | HP outer casing top and bottom halves contact checking with centre-line | 1 | Work |
3 | 73152103 | Engineering equipment maintenance services | HP outer casing center-line machining to get required contact between two halves (if required) | 1 | Work |
4 | 73152103 | Engineering equipment maintenance services | HP turbine inner casing halves center alignment | 1 | Work |
5 | 73152103 | Engineering equipment maintenance services | HP turbine inner casing crack repair by welding | 1 | Work |
6 | 73152103 | Engineering equipment maintenance services | LP inner casing top half cleaning | 1 | Work |
7 | 73152103 | Engineering equipment maintenance services | LP inner casing top and bottom halves contact checking with centre-line | 1 | Work |
8 | 73152103 | Engineering equipment maintenance services | LP inner casing center-line machining to get required contact between two halves (if required) | 1 | Work |
9 | 73152103 | Engineering equipment maintenance services | All Nozzles especially on the IP casing should be inspected | 1 | Work |
10 | 73152103 | Engineering equipment maintenance services | Repair of all cracks and defects found on the casings | 1 | Work |