Tender Details

  Published



90


COB/WSD/23/01/2025


Single Lot


Competitive Bidding Method


Non Consulting Services


Zimbabwe PPDPA Act Rules


Internally Generated Funds


CITY WIDE


Installation, Repair & Maintenance of Electrical Equipment, Generators, Power Back-Up Equipment & Miscellaneous Electrical Repair Works,Plant and Equipment Maintenance


60 Day(s)


CITY OF BULAWAYO


15-Dec-2025 02:03 PM

CITY OF BULAWAYO

Corner Fife Street and Leopold Takawira Avenue

Bulawayo, Bulawayo , Zimbabwe EMEA


FRAMEWORK AGREEMENT OF THE SERVICES FOR REHABILITATION AND MAINTENANCE OF PUMPS AND MOTORS FOR A PERIOD OF 3 YEARS

Project Name:
FRAMEWORK AGREEMENT OF THE SERVICES FOR REHABILITATION AND MAINTENANCE OF PUMPS AND MOTORS FOR A PERIOD OF 3 YEARS
Description:

FRAMEWORK AGREEMENT OF THE SERVICES FOR REHABILITATION AND MAINTENANCE OF PUMPS AND MOTORS FOR A PERIOD OF 3 YEARS

Line Item Details
Item No. UNSPSC Lot Name Lot Description Quantity Unit of Measure
1 40151716 Pump head REHABILITATION AT FERNHILL SULZER 6 - Allow to the establishment and removal of Contractor's plant, materials, site office, temporary buildings, ablutions and signboards 1 Each
2 40151716 Pump head REHABILITATION AT FERNHILL SULZER 6 - Project Funder and COB technical staff to witness approved FAT schedules at the manufacturers’ premises for the Electric motor and soft starter respectively. Note 1 electric motor and soft starter each have their own FATs unless manufactured at the same place. 5 Each
3 40151716 Pump head Contingencies 15 % 1 Each
4 40151716 Pump head FERNHILL SULZER 6 MOTOR Rewind, install, test and commission (2200kw, 6.6kv, 1470rpm 225A) motor. Change all bearings and all associated sensors. See Technical Specifications and Compliance Sheet for specifications 1 Each
5 40151716 Pump head Allow for installation, test and commission MV cable 160m x 90 mm2, 3 Core, XPLE and termination kits including all relevant accessories. Allow for decommissioning of existing cable. 1 Each
6 40151716 Pump head Allow for the new soft starter 6.6 kV, 250A for the above motor including all relevant accessories. This to include supply, installation, testing and commissioning. See Technical Specifications and Compliance Sheet below for specifications 1 Each
7 40151716 Pump head Allow for the supply, installation, testing and commission new S7-1200 PLC See Technical Specifications and Compliance Sheet below for specifications 1 Each
8 40151716 Pump head TRANSFORMERS Rewind, test and commission domestic transformer number 6 (50kva 6.6kV/400V ) including all accessories. Provide ZESA test certificate. 1 Each
9 40151716 Pump head Rewinding of 3MVA 88/6.6kV Transformer Number 6 should include but not limited to the supply of critical components of the following items without any extra cost replacing LV and HV rubber bushes, conseals, oil sampling, bulchoz servicing Supply critical components required 1 Each
10 40151716 Pump head PUMP Service the Sulzer pump and supply all worn out components that may be required and also include new bearings for the pump (7328 ball bearings and NU230) Allow for decommissioning 1 Each
11 40151716 Pump head Service and test 20-Inch non return valve. 1 Each
12 40151716 Pump head Service and test 20-Inch Rotork Actuator valve (refer to existing one on site) Allow for decommissioning 1 Each
13 40151716 Pump head Allow for lithium greasing 200kg on pumps 1 kg
14 40151716 Pump head FERNHILL CLEAR WATER 600hp 6.6kv 4 pole motors rewind and change Bearings, including all necessary accessories. Change oil gange and white metal bearings ( Bearings will be provided for refurbishment. 1 Each
15 40151716 Pump head Allow for and test 100m x 25 mm2 3 core XLPE cable including 12 x termination kits and all necessary accessories. 1 Each
16 40151716 Pump head NCEMA CLEAR WATER Clear water 480hp 6.6kv 4 pole motors rewind and change bearings (37 inch) including all related accessories. Change oil gauge and white metal bearing including all related accessories (bearings will be provided for refurbishment) 3 Each
17 40151716 Pump head Allow for and test 100 mtrs x 25 mm2 3 core XLPE cable including 12 x termination kits and all necessary accessories. 1 Each
18 40151716 Pump head Contingency (5%) 1 Each
19 40151716 Pump head Allow for the establishment and removal of Contractor's plant, materials, site office, temporary buildings, ablutions, and signboards 1 Each
20 40151716 Pump head NCEMA TRANSFORMERS Servicing of 3MVA 88/6.6kV transformers, including but not limited to oil top-up, thermography test in the station, arresting oil leaks, replacing gaskets, change of Silica gel, oil regeneration, bulchoz service and instruments, and thermography testing of the station 6 Each
21 40151716 Pump head Servicing of 50kVA 6.6/0.4kV auxiliary transformers, including but not limited to oil top-up, arresting oil leaks, replacing gaskets, changing Silica gel, oil regeneration, bulchoz service, and instrument service. 6 Each
22 40151716 Pump head FERNHILL TRANSFORMERS Servicing of 3MVA 88/6.6kV transformers, including but not limited to oil top-up, thermography testing in the substation, arresting oil leaks, replacing gaskets, changing Silica gel, oil regeneration, bulchoz service, and instruments 5 Each
23 40151716 Pump head Servicing of 50kVA 6.6/0.4kV auxiliary transformers, including but not limited to oil topping up, arresting oil leaks, replacing gaskets, changing Silica gel, oil regeneration, bulchoz Service and instruments. 5 Each
24 40151716 Pump head Contingency (5%) 1 Each
  -