Tender Details

  Published



90


COB/WSD/23G/01/2026


Single Lot


Competitive Bidding Method


Non-consultancy services


Zimbabwe PPDPA Act Rules


Procuring Entity Internal Budget Funding


Rochester and Cowdry Park, Ncema and Fernhill


Electrical Products: Cables and Materials, Power Back-Up Equipment, Transformers, Standby Generators, Consumables & Accessories,Installation, Repair & Maintenance of Electrical Equipment, Generators, Power Back-Up Equipment & Miscellaneous Electrical Repair Works


60 Day(s)


CITY OF BULAWAYO


06-May-2026 08:58 AM

CITY OF BULAWAYO

Corner Fife Street and Leopold Takawira Avenue

Bulawayo, Bulawayo , Zimbabwe EMEA


REPAIR AND MAINTENANCE OF TRANSFORMERS

Project Name:
REPAIR AND MAINTENANCE OF TRANSFORMERS
Description:

REPAIR AND MAINTENANCE OF TRANSFORMERS

Line Item Details
Item No. UNSPSC Lot Name Lot Description Quantity Unit of Measure
1 15121505 Transformer oil or insulating oil Collect oil samples before service and after service for testing, and provide the test report 10 Each
2 15121505 Transformer oil or insulating oil Disconnect the LT and reconnect the LT line on the main transformer before and after repairs 44 Each
3 15121505 Transformer oil or insulating oil Disconnect the HT and Reconnect HT line on both Main transformer before and after repairs 33 Each
4 15121505 Transformer oil or insulating oil Disconnect and Reconnect Auxiliary Transformers before and after repairs 42 Each
5 15121505 Transformer oil or insulating oil Replace gaskets on LT bushings on both the Main transformers and the Auxiliary transformers 44 Each
6 15121505 Transformer oil or insulating oil Replace gaskets on HT bushings on both the Main transformers and Auxiliary transformers 33 Each
7 15121505 Transformer oil or insulating oil Replace damaged cone seals on LT bushings on both the Main transformers and Auxiliary transformers 10 Each
8 15121505 Transformer oil or insulating oil Replace damaged cone seals on HT bushings on both the Main transformers the Auxiliary transformer 10 Each
9 15121505 Transformer oil or insulating oil Perform oil regeneration (filtration/dehydration/degassing) on the Main Transformers and Auxiliary Transformers and supply top up transformer oil 10 Each
10 15121505 Transformer oil or insulating oil Re-tighten all connections feeding and outgoing from all transformers 1 Lump Sum
11 15121505 Transformer oil or insulating oil Change silica gel 10 Each
12 15121505 Transformer oil or insulating oil Perform surge arrestor tests - Confirm mechanical tightness of ground clamp; check for signs of overheating or corrosion. 18 Each
13 15121505 Transformer oil or insulating oil Replacement of membrane (diaphragm) on transformer or conservator pressure release / pressure vacuum valves (PRVs/PVVs) 5 Each
14 15121505 Transformer oil or insulating oil Perform Leak testing and pressure/vacuum testing 10 Each
15 15121505 Transformer oil or insulating oil Provide certificates/lab reports for all oil tests 10 Each
16 15121505 Transformer oil or insulating oil Perform WB, IR and TR Test on 3MVA transformer to ZETDC standards. Provide Results. 5 Each
17 15121505 Transformer oil or insulating oil Perform WB, IR and WB Test on Auxiliary transformer to ZETDC standards. Provide Test Results 5 Each
18 15121505 Transformer oil or insulating oil Perform a thermal imaging test on transformer termination points before attending to the hot spots identified provide results. 10 Each
19 15121505 Transformer oil or insulating oil Perform a thermal imaging on transformer termination points after attending to the hot spots identified and provide results. 10 Each
20 15121505 Transformer oil or insulating oil Clean and paint main and auxiliary transformers externally 10 Lump Sum
21 15121505 Transformer oil or insulating oil Supply weed killer 40 Litre
22 15121505 Transformer oil or insulating oil Supply 400w solar lights sufficient for the transformer yard 10 Each
23 15121505 Transformer oil or insulating oil Engage ZETDC for Certifications 5 Each
24 15121505 Transformer oil or insulating oil Commission the transformers 10 Each
25 15121505 Transformer oil or insulating oil LOT 1 Ncema and Fernhill Repair and Maintenance of 3 MVA 88/6.6 kV Transformers and 50kva 6.6/0.4kv auxillary transformers Contingencies 2.5% 1 Each
26 15121505 Transformer oil or insulating oil Collect oil samples before service and after service for testing, and provide the test report 2 Each
27 15121505 Transformer oil or insulating oil Disconnect the LT and Reconnect the LT line before and after repairs 8 Each
28 15121505 Transformer oil or insulating oil Disconnect the HT and Reconnect HT line before and after repairs 6 Each
29 15121505 Transformer oil or insulating oil Replace gasket on main transformer and arrest oil leaks 1 Lump Sum
30 15121505 Transformer oil or insulating oil Replace damaged pin insulators on both HV and LV sides 14 Each
31 15121505 Transformer oil or insulating oil Replace damaged seals on HV and LV sides 14 Each
32 15121505 Transformer oil or insulating oil Re-tighten all connections feeding and outgoing from all transformers 1 Lump Sum
33 15121505 Transformer oil or insulating oil Change silica gel 2 Each
34 15121505 Transformer oil or insulating oil Perform Bulchoz service and instruments 2 Each
35 15121505 Transformer oil or insulating oil Perform surge arrestor tests - Confirm mechanical tightness of ground clamp; check for signs of overheating or corrosion. 4 Each
36 15121505 Transformer oil or insulating oil Replacement of membrane (diaphragm) on transformer or conservator pressure release / pressure vacuum valves (PRVs/PVVs) 2 Each
37 15121505 Transformer oil or insulating oil Perform Leak testing and pressure/vacuum testing 2 Lump Sum
38 15121505 Transformer oil or insulating oil Provide certificates/lab reports for all oil tests 2 Each
39 15121505 Transformer oil or insulating oil Perform WB, IR and TR Test on 1MVA transformer to ZETDC standards. Provide Results. 2 Each
40 15121505 Transformer oil or insulating oil Clean and paint transformers externally 2 Lump Sum
41 15121505 Transformer oil or insulating oil Supply weed killer 30 Litre
42 15121505 Transformer oil or insulating oil Supply 400w solar lights sufficient for the transformer yard 8 Each
43 15121505 Transformer oil or insulating oil Commission the transformers 2 Each
44 15121505 Transformer oil or insulating oil LOT 2 Rochester and Cowdry Park Repair and Maintenance of 1 MVA 11/3.3 kV Transformers Contingencies 2.5% 1 Each
  -