Published
90
COB/WKD/40E/01D/2026
Single Lot
Competitive Bidding Method
Goods
Zimbabwe PPDPA Act Rules
Procuring Entity Internal Budget Funding
Inyankuni Pump Station, Mzingwane Pump station, Aisleby 3 Sewer Treatment Plant, Criterion Water Treatment Plant
Electrical Products: Cables and Materials, Power Back-Up Equipment, Transformers, Standby Generators, Consumables & Accessories,Installation, Repair & Maintenance of Electrical Equipment, Generators, Power Back-Up Equipment & Miscellaneous Electrical Repair Works
60 Day(s)
CITY OF BULAWAYO
15-Jul-2026 11:36 AM
SUPPLY, DELIVERY AND INSTALLATION OF POWER FACTOR CORRECTION UNIT
| Project Name: SUPPLY, DELIVERY AND INSTALLATION OF POWER FACTOR CORRECTION UNIT |
| Description: SUPPLY, DELIVERY AND INSTALLATION OF POWER FACTOR CORRECTION UNIT |
| Item No. | UNSPSC | Lot Name | Lot Description | Quantity | Unit of Measure |
|---|---|---|---|---|---|
| 1 | 26121629 | Power cable | Site mobilization, preparation of shop drawings, and technical documentation | 1 | Lump Sum |
| 2 | 26121629 | Power cable | Factory Acceptance Testing (FAT) - Functional testing of APFC panel with 100% capacity check, simulation, and reports | 6 | Each |
| 3 | 26121629 | Power cable | As-built drawings, O&M manuals, and training | 1 | Lump Sum |
| 4 | 26121629 | Power cable | Contingency 5% | 1 | Each |
| 5 | 26121629 | Power cable | Supply, delivery and installation of a 400kvar Detuned Automatic Power Factor Correction (APFC) unit housed in an IP42/IP54 floor-standing enclosure, featuring an intelligent two-stage controller, over-rated power capacitors (525V), matching 7% or 5.67% copper-wound detuned reactors with bimetal thermal protection, capacitor-duty contactors, and independent HRC fuse protection. Rate to include all internal copper busbars (rated 1250A), multifunction metering, phase indicators, and Type 2 surge protection. | 1 | Each |
| 6 | 26121629 | Power cable | Supply and Install Air Circuit Breaker (ACB/MCCB), (Approx. 1250A, 3P/4P) with thermal-magnetic trip with extended handle | 1 | Each |
| 7 | 26121629 | Power cable | Supply and fix Galvanized Cable Trays (Perforated or Ladder type) (300mm-450mm) and clamp support from Main MCC to APFC location and all related accessories | 1 | Lump Sum |
| 8 | 26121629 | Power cable | Supply and Install Power Cable single Core PVC copper flex Cable 400mm2 or equivalent, (or Busbar Trunking) from MCC to PFCU | 60 | Meter |
| 9 | 26121629 | Power cable | Supply, lay and connect Earth Cable 95mm2 PVC/CU Earthing Cable | 20 | Meter |
| 10 | 26121629 | Power cable | Supply and secure Cable Glands, Lugs, shrouds, and Termination Kit for Power Cables (sizes to match cables) | 1 | Lump Sum |
| 11 | 26121629 | Power cable | Supply and secure Cantilever Arms and Threaded Rods | 1 | Lump Sum |
| 12 | 26121629 | Power cable | Supply and secure Trefoil or Single Cable Cleats (Matching Cable OD) | 1 | Lump Sum |
| 13 | 26121629 | Power cable | Supply and secure miscellaneous items PVC Sleeves, Cable Tags, Insulation Tape | 1 | Lump Sum |
| 14 | 26121629 | Power cable | Supply and install 1000kVA (1MVA) 3-Phase Air-Cooled Servo Controlled Voltage Stabilizer (Input 415V±25%, Output 400V±1%, 50Hz) complete with columnar variable transformers, buck/boost transformers, motorized 1250A incoming/outgoing MCCBs, and a manual bypass changeover switch. Includes microprocessor control, servo motor drive, and digital display for V, I, and F | 1 | Each |
| 15 | 26121629 | Power cable | Perform No-load and Full-load testing report (Internal) | 1 | Lump Sum |
| 16 | 26121629 | Power cable | Provide Operation & Maintenance Manuals | 1 | Lump Sum |
| 17 | 26121629 | Power cable | Perform all required tests, provide test certificates and commission the entire system. | 1 | Lump Sum |
| 18 | 26121629 | Power cable | Site mobilization, preparation of shop drawings, and technical documentation | 1 | Lump Sum |
| 19 | 26121629 | Power cable | Factory Acceptance Testing (FAT) - Functional testing of APFC panel with 100% capacity check, simulation, and reports. | 6 | Each |
| 20 | 26121629 | Power cable | As-built drawings, O&M manuals, and training | 1 | Lump Sum |
| 21 | 26121629 | Power cable | Contingency 5% | 1 | Each |
| 22 | 26121629 | Power cable | Supply, delivery and installation of a 400kvar Detuned Automatic Power Factor Correction (APFC) unit housed in an IP42/IP54 floor-standing enclosure, featuring an intelligent two-stage controller, over-rated power capacitors (525V), matching 7% or 5.67% copper-wound detuned reactors with bimetal thermal protection, capacitor-duty contactors, and independent HRC fuse protection. Rate to include all internal copper busbars (rated 1250A), multifunction metering, phase indicators, and Type 2 surge protection. | 1 | Each |
| 23 | 26121629 | Power cable | Supply and Install Air Circuit Breaker (ACB/MCCB), (Approx. 1250A, 3P/4P) with thermal-magnetic trip with extended handle | 1 | Each |
| 24 | 26121629 | Power cable | Supply and fix Galvanized Cable Trays (Perforated or Ladder type) (300mm-450mm) and clamp support from Main MCC to APFC location and all related accessories | 1 | Lump Sum |
| 25 | 26121629 | Power cable | Supply and Install Power Cable single Core PVC copper flex Cable 400mm2 or equivalent, or Busbar Trunking) from MCC to PFCU sized for 1000kVA and all related accessories | 60 | Meter |
| 26 | 26121629 | Power cable | Supply, lay and connect Earth Cable 95mm2 PVC/CU Earthing Cable | 20 | Meter |
| 27 | 26121629 | Power cable | Supply and secure Cable Glands, Lugs, shrouds, and Termination Kit for Power Cables (sizes to match cables) | 1 | Lump Sum |
| 28 | 26121629 | Power cable | Supply and secure Cantilever Arms and Threaded Rods | 1 | Lump Sum |
| 29 | 26121629 | Power cable | Supply and secure Trefoil or Single Cable Cleats (Matching Cable OD) | 1 | Lump Sum |
| 30 | 26121629 | Power cable | Supply and secure miscellaneous items PVC Sleeves, Cable Tags, Insulation Tape | 1 | Lump Sum |
| 31 | 26121629 | Power cable | Supply and install 1000kVA (1MVA) 3-Phase Air-Cooled Servo Controlled Voltage Stabilizer (Input 415V±25%, Output 400V±1%, 50Hz) complete with columnar variable transformers, buck/boost transformers, motorized 1250A incoming/outgoing MCCBs, and a manual bypass changeover switch. Includes microprocessor control, servo motor drive, and digital display for V, I, and F | 1 | Each |
| 32 | 26121629 | Power cable | Perform No-load and Full-load testing report (Internal) | 1 | Lump Sum |
| 33 | 26121629 | Power cable | Provide Operation & Maintenance Manuals and training | 1 | Lump Sum |
| 34 | 26121629 | Power cable | Perform all required tests, provide test certificates and commission the entire system. | 1 | Lump Sum |
| 35 | 26121629 | Power cable | Site mobilization, preparation of shop drawings, and technical documentation | 1 | Lump Sum |
| 36 | 26121629 | Power cable | Factory Acceptance Testing (FAT) - Functional testing of APFC panel with 100% capacity check, simulation, and reports. | 6 | Each |
| 37 | 26121629 | Power cable | As-built drawings, O&M manuals, and training | 1 | Lump Sum |
| 38 | 26121629 | Power cable | Contingency 5% | 1 | Each |
| 39 | 26121629 | Power cable | De-commissioning and disconnection of existing 200kvar PF unit and all related cabling. | 1 | Each |
| 40 | 26121629 | Power cable | Environmentally compliant disposal/scrapping of the old dry unit (Engineer to advise the location) | 1 | Lump Sum |
| 41 | 26121629 | Power cable | Modification of mounting base Steel channel adapters to match new reactor footprint to existing floor bolts | 1 | Lump Sum |
| 42 | 26121629 | Power cable | Supply, delivery and installation of a 300kvar Detuned Automatic Power Factor Correction (APFC) unit housed in an IP42/IP54 floor-standing enclosure, featuring an intelligent two-stage controller, over-rated power capacitors (525V), matching 7% or 5.67% copper-wound detuned reactors with bimetal thermal protection, capacitor-duty contactors, and independent HRC fuse protection. Rate to include all internal copper busbars (rated 630A), multifunction metering, phase indicators, and Type 2 surge protection. | 1 | Each |
| 43 | 26121629 | Power cable | Supply and Install Air Circuit Breaker (ACB) or MCCB (Approx. 630A, 3P/4P) with thermal-magnetic trip with extended handle | 1 | Each |
| 44 | 26121629 | Power cable | Supply and fix Perforated Cable Trays (300mm-450mm) including glands, lugs, and clamp support from Main MCC to APFC location and all related accessories | 1 | Lump Sum |
| 45 | 26121629 | Power cable | Supply and Install Power Cable single Core flex CU PVC Cable 240mm2 or equivalent, or Busbar Trunking) from MCC to PFCU and all related accessories. | 40 | Meter |
| 46 | 26121629 | Power cable | Supply and secure Cable Glands, Lugs, and Termination Kit for Power Cables | 1 | Lump Sum |
| 47 | 26121629 | Power cable | Supply, lay and connect Earth Cable 70mm2 PVC/CU Earthing Cable | 10 | Meter |
| 48 | 26121629 | Power cable | Provide Operation & Maintenance Manuals and Training | 1 | Lump Sum |
| 49 | 26121629 | Power cable | Perform all required tests, provide test certificates and commission the entire system. | 1 | Lump Sum |
| 50 | 26121629 | Power cable | Supply, delivery and installation of a 250kvar Detuned Automatic Power Factor Correction (APFC) unit housed in an IP42/IP54 floor-standing enclosure, featuring an intelligent two-stage controller, over-rated power capacitors (525V), matching 7% or 5.67% copper-wound detuned reactors with bimetal thermal protection, capacitor-duty contactors, and independent HRC fuse protection. Rate to include all internal copper busbars (rated 400A), multifunction metering, phase indicators, and Type 2 surge protection. | 1 | Each |
| 51 | 26121629 | Power cable | Supply and Install Air Circuit Breaker (ACB) or MCCB (Approx. 400A, 3P/4P) with thermal-magnetic trip with extended handle | 1 | Each |
| 52 | 26121629 | Power cable | Supply and fix Perforated Cable Trays (300mm-450mm) including glands, lugs, and clamp support from Main MCC to APFC location and all related accessories | 1 | Lump Sum |
| 53 | 26121629 | Power cable | Supply and Install Power Cable single Core PVC copper flex Cable 185mm2 or equivalent, or Busbar Trunking) from MCC to PFCU and all related accessories | 40 | Meter |
| 54 | 26121629 | Power cable | Supply and secure Cable Glands, Lugs, and Termination Kit for Power Cables | 1 | Lump Sum |
| 55 | 26121629 | Power cable | Supply, lay and connect Earth Cable 50mm2 PVC/CU Earthing Cable | 10 | Meter |
| 56 | 26121629 | Power cable | Provide Operation & Maintenance Manuals | 1 | Lump Sum |
| 57 | 26121629 | Power cable | Provide Operation & Maintenance Manuals and Training | 1 | Lump Sum |
| 58 | 26121629 | Power cable | Perform all required tests, provide test certificates and commission the entire system. | 1 | Lump Sum |